PANDUIT: Electrical Full Line

ELECTRICAL SOLUTIONS C2.32 B2. Cable Accessories C1. Wiring Duct C3. Abrasion Protection C4. Cable Management D1. Terminals D2. Power Connectors E1. Labeling Systems E2. Labels E3. Pre-Printed & Write-On Markers F. Index B3. Stainless Steel Ties C2. Surface Raceway E5. Lockout/ Tagout & Safety Solutions B1. Cable Ties A. System Overview D3. Grounding Connectors E4. Permanent Identification Cable fill #4: Power and data using a wire retainer and divider walls. A = 0.44 in. 2 Cable fill #5: Power and data using the offset box. B = 0.68 in. 2 C = 0.44 in. 2 A = 0.41 in. 2 B = 1.06 in. 2 Cable Fill Capacities for T-45 Raceway This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to the cable installation methods, straightness of cables, etc. Cable fill #1: T-45 with no devices. A = 2.13 in. 2 Cable fill #2: T-45 with wire retainer. A = 1.72 in. 2 Cable fill #3: Power and data using a wire retainer and divider wall. B = 1.20 in. 2 SPEC = 40% cable fill – The recommended design in cable capacity, leaves room for future moves, adds, and changes. A = 0.44 in. 2 Cable fill #8: Power and data using electrical bracket/box and hinged data bracket. A = 0.22 in. 2 Cable fill #7: Power and data using hinged data bracket with divider insert. Cable fill #6: Data only using hinged data bracket. A = 2.00 in. 2 A = 0.52 in. 2 B = 1.20 in. 2 B = 0.50 in. 2 AWG dimensions represent typical outer cable diameter in inches. MAX for Data = 60% cable fill – The maximum cable quantity based on cable interweaving and packing factors. MAX for Power cable fill – The maximum of electrical cables based on UL temperature rise test. CR-SR-T45-WireFill1 Raceway Type and Configuration Fill Area (In.²) Electrical Cables Data Grade Cables Data Grade Cables Audio/Video Fiber Optic Cable 14 AWG 12 AWG 10 AWG 23/24 AWG/UTP 23 AWG/UTP CM RG6 2 Strand THHN/T90 Cat 6. (4-pr.) Augmented Cat. 6 0.111 0.130 0.164 DIA. = .250 DIA. = .354 DIA. = .275 DIA. = .175 FILL FILL FILL FILL FILL MAX MAX MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX (UL Temp Rise Test) (40%) (60%) (40%) (60%) (40%) (60%) (40%) (60%) 1. T-45: No devices. 2.13 36 27 25 17 26 9 14 14 21 35 53 2. T-45: No devices with wire retainer. 1.72 36 27 25 14 21 8 12 11 17 28 42 3A. T-45: Power and data with wire retainer and divider wall (2 channels). 0.44 12 11 8 — — — — — — — — 3B. 1.20 — — — 9 14 5 8 8 12 19 29 4A. T-45: Power and data with wire retainer and two divider walls (three channels). 0.44 12 11 8 3 5 2 3 2 4 7 10 4B. 0.68 — — — 5 8 3 4 4 6 11 16 4C. 0.44 — — — 3 5 2 3 2 4 7 10 5A. T-45: Power and data using the offset box. 0.41 12 11 8 — — — — — — — — 5B. 1.06 — — — 8 12 4 7 7 10 17 26 6. T-45: Data only using data bracket. 2.00 — — — 16 24 9 14 13 20 33 49 7A. T-45: Power and data using hinged data bracket with divider insert. 0.52 12 11 8 — — — — — — — — 7B. 1.20 — — — 9 14 5 8 8 12 19 29 8A. T-45: Power and data using electrical bracket and box. 0.22 9 7 4 — — — — — — — — 8B. 0.50 — — — 4 6 2 3 3 5 8 12

RkJQdWJsaXNoZXIy Mjg1MjI=