PANDUIT: Electrical Full Line

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory) ELECTRICAL SOLUTIONS C2.23 B2. Cable Accessories C1. Wiring Duct C3. Abrasion Protection C4. Cable Management D1. Terminals D2. Power Connectors E1. Labeling Systems E2. Labels E3. Pre-Printed & Write-On Markers F. Index B3. Stainless Steel Ties C2. Surface Raceway E5. Lockout/ Tagout & Safety Solutions B1. Cable Ties A. System Overview D3. Grounding Connectors E4. Permanent Identification a b a b Cable Fill Capacities for T-70 Raceway This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to the cable installation methods, straightness of cables, etc. Cable fill #1: Raceway with no devices. A = 5.15 in. 2 Cable fill #2: Power and data using 3-sided hanging box and device bracket. A = .86 in. 2 Cable fill #3: Data only using vertical sloped screw-on communication faceplates. A = 3.67 in. 2 Cable fill #4: Data only using horizontal sloped snap-on communication faceplates. A = 4.71 in. 2 Cable fill #5: Power and data using the Workstation Outlet Center ™ Offset Box. A = .91 in. 2 A = 3.12 in. 2 SPEC = 40% cable fill – The recommended design in cable capacity, leaves room for future moves, adds, and changes. MAX for Data = 60% cable fill – The maximum cable quantity based on cable interweaving and packing factors. MAX for Power cable fill – The maximum of electrical cables based on UL temperature rise test. A = 1.72 in. 2 AWG dimensions represent typical outer cable diameter in inches. CR-SR-T70-WireFill1 Raceway Type and Configuration Fill Area (In.²) Electrical Cables Data Grade Cables Data Grade Cables Audio/Video Fiber Optic Cable 14 AWG 12 AWG 10 AWG 24 AWG/UTP CM 24 AWG/UTP CM RG6 2 Strand THHN/T90 Cat 6. (4-pr.) Augmented Cat. 6 0.111 0.130 0.164 DIA. = 0.250 DIA. = 0.330 DIA. = 0.275 DIA. = 0.175 FILL FILL FILL FILL FILL MAX MAX MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX (UL Temp Rise Test) (40%) (60%) (40%) (60%) (40%) (60%) (40%) (60%) 1. T-70: No devices. 5.15 24 20 15 41 62 24 36 34 52 85 128 2a. T-70: Power and data using the 3-sided hanging box and device bracket. 0.86 14 11 7 — — — — — — — — 2b. 1.72 — — — 14 21 8 12 11 17 28 42 3. T-70: Data only (screw-on faceplates). 3.67 — — — 29 44 17 25 24 37 61 91 4. T-70: Data only (snap-on faceplates). 4.71 — — — 38 57 22 33 31 47 78 117 5a. T-70: Power and data using the Workstation Outlet Center ™ Offset Box. 0.91 14 11 7 — — — — — — — — 5b. 3.12 — — — 25 38 14 21 21 31 51 77

RkJQdWJsaXNoZXIy Mjg1MjI=